上海九游会集团产品机电设备有限公司-燃烧器,燃烧机配件,DUNGS电磁阀,冬斯电磁阀,西门子控制器,SUNTEC油泵

产品中心

Our Products

LAE10火焰监测器 的详细介绍:

LAE10系列火焰监测器

 

品牌:SIEMENS(西门子)(原LANDIS&GYR)

产地:德国

产品介绍

LFE10和LAE10都为配合西门子专用火焰探测器使用的火焰检测器。

LFE10可以与SIEMENS西门子公司的QRA...系列火焰探测器或者离子探针配合使用,把模拟量电流信号转换为开关量信号,并输出给燃烧器程控器。

LAE10可以与SIEMENS西门子公司的RAR...系列燃油火焰探测器配合使用,把模拟量电流信号转换为开关量信号,并输出给燃烧器程控器。

此两款火焰检测器必须每24小时停止工作一次。如需要24小时连续工作,请选用LFE50系列产品。

Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit, etc. - at least one controlled

shutdown is required every 24 hours. The LFE10 is suited for the supervision of gas flames and luminous or blue-burning oil flames in connection with UV detectors QRA... or a flame rectification probe.

Flame safeguards are used primarily in conjunction with the LEC1 burner control on the following applications:

  • Dual-supervision of burners: Supervision of the main flame or of the pilot and main flame by two identical or different types of flame detectors

  • Supervision of forced draught oil / gas burners: Supervision of the flame with different types of detectors, depending on the operating mode

  • Multi-flame supervision: Plants with several burners whose flames must be supervised individually by one or several detectors, whose startup and supervision, however, should or must be carried out centrally and simultaneously by only one burner control

  • The flame safeguards can also be used in connection with other types of burner controls provided the given combination and selected circuitry do not impair the burner controls safety functions

  • The flame safeguards are also used as flame indication units in combustion plant with manual startup

技术参数
主要参数
主电压 AC220V -15%...AC240V +10%
AC100V -15%...AC1100V +10%
主频率 50...60Hz ±6%
外部保险丝 10A
功率 4.5VA
端口额定电流 2A
保护等级 IP40
重量(不含底座) 395g
环境条件
运输环境 IEC 60 721-3-2
内部条件 class 2K2
机械条件 class 2M2
温度范围 -20...+60ºC
湿度 <95%
运行环境 IEC 60 721-3-3
内部条件 class 3K5
机械条件 class 3M2
温度范围 -20...+60ºC
湿度 <95%
不得进水
电源LAE10LFE10最小探测电流在AC100V/AC220V下在AC110V/AC240V下最大探测电流在AC100-110V/AC220-240V下允许最大电线长度
RAR系列 离子探针 QRA系列
8uA 8uA 150uA
8uA 9uA 200uA
25uA 100uA 650uA
20m 20m 20m
电路图1 - 2台LAE10连接RAR火焰探测器,与LEC1燃烧器控制器连接

电路图2 - 3台LFE10连接QRA火焰探测器或者离子探针,与LEC1燃烧器控制器连接

 